Nivisys, LLC Rev. 14 Aug 2014
3-6
A second calibration is suggested at 30 seconds after powering
ON the unit. This allows the thermal sensor to adjust to the
surrounding temperatures. Additional calibrations may be
required as surrounding temperature changes or any time a
fixed, non-uniform shading appears on the display screen.
Figure 3-4 Calibration
3.7 Range Focus Adjustment (60mm and 100mm Lenses):
The range focus ring is used to focus the objective lens for
objects viewed at varied distances. Rotate the range focus ring
counter-clockwise for distant objects up to infinity. Rotate the
range focus ring clockwise for close objects.
The 60mm lens is indicated by an “L” in the model name and
can focus to 2 meters. The 100mm lens is indicated by an “E”
in the model name and can focus to 10 meters.